高(gao)低(di)壓(ya)開(kai)關(guan)櫃(gui)通電(dian)試(shi)驗(yan)臺(tai)過(guo)電壓(ya)試驗試(shi)驗(yan)步驟(zhou)
更新時(shi)間(jian):2022-09-01
點(dian)擊(ji)次數(shu):2901
高(gao)低(di)壓(ya)開(kai)關(guan)櫃(gui)通電(dian)試(shi)驗(yan)臺(tai)過(guo)電壓(ya)試驗試(shi)驗(yan)步驟(zhou)
高(gao)低(di)壓(ya)開(kai)關(guan)櫃(gui)通電(dian)試(shi)驗(yan)臺(tai)電(dian)容櫃1.1倍(bei)過電(dian)壓(ya)試驗步驟(zhou):
1)試(shi)驗之前(qian),先(xian)要(yao)弄清(qing)電(dian)容櫃控制(zhi)器的過(guo)電(dian)壓(ya)值是多(duo)少(控(kong)制(zhi)器說明(ming)書(shu)中均(jun)會(hui)提(ti)到(dao)或按(an)照國(guo)家標準(zhun)額(e)定電(dian)壓(ya)的1.1倍(bei)),將該數(shu)值(zhi)設(she)定在交流(liu)電壓(ya)表中;
2)檢(jian)查與電(dian)容櫃的連(lian)線(xian)是(shi)否正確(que),試(shi)驗(yan)時(shi)只需(xu)將交流(liu)0-460V輸出(chu)的四(si)根導(dao)線連(lian)接(jie)於(yu)電(dian)容櫃控制(zhi)器相應(ying)的(de)A、B、C、N,將之前(qian)連(lian)接(jie)控(kong)制(zhi)器的導(dao)線(xian)脫開(kai);
3)檢(jian)查地線(xian)連(lian)接(jie),輸入A、B、C、N等(deng)導線(xian)是否正確(que)連(lian)接(jie)到(dao)通電(dian)試驗(yan)臺中,壹(yi)切(qie)都(dou)檢查無(wu)誤(wu)後就(jiu)可開(kai)始(shi)試驗(yan)了;
4)合(he)上(shang)總(zong)電(dian)源(yuan)開(kai)關(guan),再(zai)合(he)上(shang)0-460V交流(liu)輸出(chu)控制(zhi),此時(shi)合(he)閘(zha)燈(deng)亮,緩(huan)慢(man)調(tiao)節(jie)電(dian)壓(ya)調(tiao)壓(ya)器,監(jian)視(shi)電壓(ya)表上(shang)的(de)讀(du)數(shu),當(dang)通(tong)電(dian)試(shi)驗(yan)臺輸出(chu)電壓(ya)達到(dao)預先(xian)設定(ding)的電壓(ya)後,此時(shi)會(hui)聽(ting)到(dao)控制(zhi)器動(dong)作(zuo)的聲音,電(dian)秒表(biao)開(kai)始(shi)計(ji)時,當(dang)控(kong)制(zhi)器設定(ding)的(de)時間(jian)到(dao)後,電秒表停止計(ji)時,並將動(dong)作(zuo)時間(jian)保(bao)持在屏(ping)幕(mu)上(shang);
5)調(tiao)節(jie)調(tiao)壓(ya)器到(dao)零位(wei),並按下交流(liu)分(fen)閘控(kong)制(zhi)按(an)鈕;
高(gao)低(di)壓(ya)開(kai)關(guan)櫃(gui)通電(dian)試(shi)驗(yan)臺(tai)電(dian)容櫃的補償試(shi)驗(yan)操(cao)作(zuo)步驟(zhou):
1)將固(gu)定(ding)380V輸出(chu)的交流(liu)輸出(chu)線與(yu)控(kong)制(zhi)器中的(de)A、B、C、N相連(lian),將0-10A交流(liu)電流(liu)補償輸出(chu)線與(yu)控(kong)制(zhi)器的IA、IB、IC、N相連(lian);
2)檢(jian)查輸入電(dian)源(yuan)線(xian)和(he)地線(xian)是否連(lian)接(jie)正確(que);
3)合(he)上(shang)總(zong)電(dian)源(yuan)開(kai)關(guan),緩(huan)慢(man)調(tiao)節(jie)控(kong)制(zhi)電(dian)流(liu)輸出(chu)的調(tiao)壓(ya)器,監(jian)視(shi)電流(liu)表中的(de)電流(liu)值,當(dang)輸出(chu)電流(liu)達到(dao)5A時,停止調(tiao)節(jie),切(qie)換(huan)電流(liu)輸出(chu)開(kai)關(guan)至(zhi)電(dian)容補償試(shi)驗(yan),此時(shi)控制(zhi)器補償投(tou)入,再(zai)將電流(liu)選擇(ze)開(kai)關(guan)切(qie)換(huan)到(dao)退出(chu)位置,控制(zhi)器應該(gai)退出(chu);
4)若控(kong)制(zhi)器沒有(you)正常動(dong)作(zuo),請檢查接(jie)線(xian),再(zai)次按(an)照上(shang)述(shu)步驟(zhou)重(zhong)復操(cao)作(zuo);
5)需(xu)要(yao)註意(yi)的(de)是(shi)接(jie)線(xian)時(shi)要(yao)註意(yi)相序是否正確(que),包(bao)括(kuo)380V輸入電(dian)壓(ya)的相序(即A,B,C,N是否正確(que))和(he)輸出(chu)相序(即輸出(chu)的A,B,C,N是(shi)否對應(ying)的連(lian)接(jie)無(wu)誤(wu));
所(suo)有(you)試驗(yan)做完畢(bi)後,先將輸出(chu)調(tiao)節(jie)旋(xuan)扭(niu)逆(ni)時針(zhen)旋(xuan)轉至(zhi)零位(wei),再(zai)斷開(kai)總(zong)電(dian)源(yuan)開(kai)關(guan),確(que)定(ding)所(suo)有(you)交流(liu)電已經(jing)切(qie)除(chu)後,才(cai)能開(kai)始(shi)拆線。
公(gong)司(si)郵箱: [email protected]
服(fu)務(wu)熱線(xian): 027-86536268
公(gong)司(si)地址: 中國(guo)湖北(bei)武漢(han)市(shi)東(dong)西湖區(qu)中國(guo)臺(tai)灣(wan)源(yuan)源(yuan)鑫(xin)工(gong)業園B棟(dong)
Copyright © 2026 武漢(han)華(hua)圖(tu)高(gao)電(dian)電氣(qi)科技(ji)有(you)限公(gong)司(si) All Rights Reserved